Submersible 3 - Core Flat Cables
Our Submersible 3 - Core Flat Cables are a specialized product, which is
used for submersible pumps in deep wells. The environment is very
uncongenial and also area of installation is physically restrictive. Kundan
cab Submersible 3 - Core Flat Cables are manufactured and designed to attain
the highest possible degree of reliability and meet the above factors.
 |
Range of Submersible 3 - Core Flat Cables
1.5 Sq mm to 50 Sq mm Submersible 3 - Core
Flat Cables
 |
These cables are manufactured keeping in mind the severe and difficult
conditions in which they are required to perform. They are made from bright
electrolytic grade copper. Proper care is taken during the manufacturing
process to ensure flexibility and uniform resistance. They are properly
drawn, annealed and bunched in order to maximize their performance. Special
PVC compound is used to insulate each of the 3 copper conductors from each
other. The cores are laid up in flat parallel position. Finally, the outer
sheath of the cable is made from a special grade of abrasion resistance PVC
compound, which is impervious to water, grease, oil etc.
3 Core Flat Cables as per IS:694:1990 with ISI
mark
| Conductor |
Insulation |
Sheath
Overall Dimensions |
Conductor Resistance
@20°C (max.) ohms/km. |
Current Carrying
Capacity @ 40°C (Amp.) |
| Area (Nom.) Sq. mm. |
No./size of Wires mm |
Thickness (Nom) mm. |
Core Dia. (Nom) mm. |
Thickness (Nom) mm. |
Width 'W' mm |
Thickness 'T' mm |
| 1.5 |
22/0.3 |
0.8 |
3.25 |
1.15 |
12.5 |
5.8 |
12.10 |
14 |
| 2.5 |
36/0.3 |
0.9 |
3.90 |
1.15 |
14.4 |
6.3 |
7.41 |
18 |
| 4 |
56/0.3 |
1.0 |
4.65 |
1.15 |
17.2 |
7.4 |
4.95 |
26 |
3 Core Flat Cables generally conforming to
IS:694:1990
| Conductor |
Insulation |
Sheath
Overall Dimensions |
Conductor Resistance
@ 20°C (max.) ohms/km. |
Current Carrying
Capacity @ 40°C (Amp.) |
| Area (Nom.) Sq. mm. |
No./size of Wires mm |
Thickness (Nom) mm. |
Core Dia. (Nom) mm. |
Thickness (Nom) mm. |
Width 'W' mm |
Thickness 'T' mm |
| 6.0 |
84/0.3 |
1.0 |
5.20 |
1.15 |
18.7 |
7.9 |
3.30 |
31 |
| 10.0 |
140/0.3 |
1.0 |
6.60 |
1.40 |
23.7 |
9.9 |
1.91 |
42 |
| 16.0 |
226/0.3 |
1.0 |
8.20 |
1.40 |
28.0 |
11.4 |
1.21 |
57 |
Selection Guide for 3 Core Flat Cables
1) HP Vs Current: The full load current for submersible pump motors, 3
phase, 50 cycles, 415~425 V.
| Hp |
5.0 |
7.5 |
10.0 |
12.5 |
15.0 |
17.5 |
20.0 |
25.0 |
30.0 |
35.0 |
40.0 |
45.0 |
50.0 |
55.0 |
60.0 |
65.0 |
70.0 |
75.0 |
80.0 |
| Amp |
7.5 |
11.0 |
14.9 |
18.9 |
22.5 |
25.2 |
28.4 |
35.6 |
42.3 |
50.4 |
58.1 |
62.1 |
67.5 |
73.8 |
81.0 |
87.3 |
93.6 |
100.80 |
108.0 |
2) Derating Factors: Multiply the current carrying capacity of the cable by
factors given below for various ambient temperatures.
| Ambient Temperature C |
30 |
35 |
40 |
45 |
50 |
| Operating Factor |
1.09 |
1.04 |
1.00 |
0.95 |
0.77 |